Global Medical Device Podcast powered by Greenlight Guru

Greenlight Guru + Medical Device Entrepreneurs

Details

The Global Medical Device Podcast, powered by Greenlight Guru, is where today's brightest minds in the medical device industry go to get their most useful and actionable insider knowledge, direct from some of the world's leading medical device experts and companies.

Recent Episodes

NOV 25, 2026
#477: De Novo vs. 510(k): Turning FDA Regulation into a Competitive Moat with Mike Drues
In this episode of the Global Medical Device Podcast, host Etienne Nichols and returning guest Mike Drues, Ph.D., examine why the FDA De Novo pathway—designed for novel, low- to moderate-risk medical devices—has one of the lowest authorization rates and a declining number of industry submissions. Mike traces the evolution of the pathway from its burdensome 1998 origins to its 2009 overhaul and upcoming MDUFA shifts. Together, they unpack why "no predicate" is a common regulatory misconception, how innovators can use a De Novo as a competitive moat rather than a compliance hurdle, and why investor reluctance, benefit-risk expectations, and clinical data myths are driving submissions down. Takeaways "No Predicate" Is a Myth: You can almost always find a distant predicate for any device. A De Novo is for when there is no suitable predicate or product code to support a viable substantial equivalence argument. Apply the 3-Part Novelty Litmus Test: Before calling a device novel, ask if there is existing regulation, guidance, or reimbursement for it. If the answer to any is yes, it likely is not truly novel. Turn Regulation into a Competitive Moat: Even if a device could clear via a 510(k), pursuing a De Novo and embedding a proprietary performance claim into your intended use labeling makes it much harder for competitors to use your device as a predicate. De Novo Requires Proving Benefit, Not Just Mitigating Risk: Unlike a standard 510(k)—where benefit is largely assumed via the predicate—a De Novo requires demonstrating meaningful benefit alongside risk controls to justify down-classifying from default Class III. Fast FDA Decisions Don't Mean Easy Approvals: While the FDA hits its 150-day review target well above MDUFA goals, tight Additional Information Request (AIR) turnarounds and investor hesitation around cost and clinical data continue to depress submission volumes. References Guest: Mike Drues, Ph.D.— President, Vascular Sciences Regulatory Concepts & Frameworks Mentioned:FDA De Novo Classification Request Pathway (1998 FDAMA origins, 2009/FDASIA direct De Novo updates, and upcoming MDUFA/Gen 3 changes) FDA 510(k) Premarket Notification & Substantial Equivalence FDA Premarket Approval (PMA) & Default Class III Classification Medical Device User Fee Amendments (MDUFA) Review Goals & Additional Information Requests (AIRs) AdvaMed (referenced regarding De Novo grant rate commentary) Feedback Call-to-Action Have you navigated a De Novo submission or weighed a De Novo against a 510(k) for a novel device? Share your experience or suggest a regulatory topic for an upcoming episode by reaching out to the Global Medical Device Podcast team at [email protected] or leaving a rating and review on Apple Podcasts and Spotify.
41 MIN
OCT 15, 2026
#476: Part 2: FDA Guidance: What We Should Expect in 2027
In this episode of the Global Medical Device Podcast, host Etienne Nichols continues his conversation with regulatory consultant Michael Drues, Ph.D., to examine the FDA's Center for Devices and Radiological Health (CDRH) guidance document priorities for fiscal year 2027. The discussion kicks off with a critical evaluation of the A-list, B-list, and under construction categories, analyzing the agency's timeline commitments and the practical realities behind how regulatory priorities are established and executed. The conversation explores specific topics featured on the lists, ranging from AI-enabled device software functions and predetermined change control plans (PCCPs) to more traditional products like respirators and menstrual devices. Dr. Drues shares his perspective on the distinction between wellness devices and those intended for medical purposes, emphasizing the importance of reading between the lines of regulatory text. Finally, the dialogue delves into broader structural questions surrounding FDA transparency, resource allocation, and how medical device professionals can effectively engage with the agency during the public comment period. Listeners are provided with practical insights on navigating evolving regulatory expectations and submitting comments before the November 30 deadline. Takeaways Monitor the Guidance Lists: Review the CDRH A-list and B-list priorities early to align your R&D and regulatory submission timelines with upcoming FDA expectations. Understand Regulatory Intent: Recognize that placement on the A-list reflects CDRH's stated intent rather than a hard guarantee, meaning manufacturers must build flexibility into their regulatory strategies. Distinguish Medical Purpose from Wellness: When reviewing product codes and guidance, carefully evaluate how the FDA defines medical intended use versus general wellness to avoid unexpected classification hurdles. Participate in Public Comments: Take advantage of the public comment window open until November 30 to provide actionable data and feedback on guidance priorities that impact your specific device portfolio. References CDRH Guidance Document Database: The primary repository for published FDA draft and final guidance documents. Etienne Nichols on LinkedIn: Connect with host Etienne Nichols for ongoing medical device discussions and industry updates atEtienne Nichols' LinkedIn. Sponsors This episode is brought to you by Greenlight Guru. Navigating complex regulatory landscapes like the FDA's fiscal year priorities requires a robust quality management system and efficient data management. Greenlight Guru's industry-leading Quality Management System (QMS) and Electronic Data Capture (EDC) solutions are built specifically for the medical device industry, helping you bring life-changing products to market faster and with total compliance confidence. Visit Greenlight Guru to streamline your design controls, risk management, and clinical data workflows today. Feedback Call-to-Action We want to hear from you! Your feedback helps shape future episodes and ensures we bring you the most relevant regulatory and engineering insights in the MedTech industry. Please leave a review, share your thoughts, or suggest future episode topics by reaching out directly to our team at [email protected]. We personally read and respond to every message we receive.
52 MIN
OCT 13, 2026
#475: Part 1: Rethinking FDA Guidance: Why Non-Binding Documents Define Your Regulatory Strategy
In this episode of the Global Medical Device Podcast, host Etienne Nichols and regulatory consultant Mike Drues dive deep into the world of FDA guidance documents. They unpack what these documents truly represent—the agency's current thinking rather than binding law—and explore how manufacturers can navigate them effectively. The discussion covers the distinction between regulations in the Code of Federal Regulations and agency guidance, highlighting why a rigid, literal interpretation can be dangerous for product development. The conversation examines the practical realities of using guidance documents as tactical tools and highlights the importance of proactive engagement with the agency. Mike shares valuable insights on challenging assumptions, understanding the shades of gray in regulatory compliance, and the strategic advantages of addressing deviations early through the pre-submission process. They also touch upon the limitations of the FDA guidance database and why revision history matters. As part one of a two-part series, this episode lays the critical foundation for understanding how guidance shapes medical device development. Listeners will gain a fresh perspective on interacting with the FDA, moving beyond compliance checkboxes to build robust, defensible regulatory strategies. Stay tuned for part two, where the discussion shifts specifically to the fiscal year 2027 guidance list. Takeaways Understand the distinction: Recognize that regulations in the CFR carry legal weight originating from Congress, whereas guidance documents represent FDA's current administrative or technical thinking and are technically non-binding. Avoid absolutism: Do not treat guidance documents as immutable laws; manufacturers can propose alternative approaches if they satisfy statutory and regulatory requirements. Leverage the pre-sub process: If your device strategy diverges from a published guidance document, address the deviation proactively during a pre-submission meeting rather than waiting for a rejection on your final submission. Look beyond the database: Use multiple search avenues—including broader web searches and direct inquiries through OICE/Dice—to track updates, historical revisions, and guidance documents currently in development. References 21 CFR Part 10.115 - FDA’s Good Guidance Practices regulation outlining how guidance documents are developed and utilized. CDRH Guidance Document Database - The primary repository for current FDA medical device guidance documents. Etienne Nichols' LinkedIn - Connect with Etienne Nichols for more MedTech discussions and insights. Sponsors Greenlight Guru provides an industry-leading MedTech quality management solution that integrates both powerful QMS and EDC software onto a single platform. Feedback Call-to-Action We want to hear from you! What topics would you like us to cover in future episodes, or how are you navigating FDA guidance updates in your current projects? Send your thoughts, feedback, and topic suggestions directly to [email protected], and our team will provide a personalized response. Don't forget to leave us a review!
34 MIN
SEP 22, 2026
#470: The Real Cost of MedTech Innovation: From Idea to Pre-Production with Lisa Voronkova
Building a medical device rarely follows the smooth, predictable trajectory presented in investor pitch decks. While regulatory consultants often default to "it depends," medical device teams require concrete figures regarding engineering hours, calendar timelines, and budget allocations to bring a concept to market safely and effectively. Lisa Voronkova, co-founder of OVA Solutions, draws on a dataset from developing over 200 medical devices to pull back the curtain on hardware engineering realities. She outlines the four structured phases of engineering—Discovery, Proof of Concept, Design, and Development—explaining how disciplined phase-gate management mitigates costly late-stage redesigns and protects capital. The conversation dives into transparent, real-world case studies ranging from short pre-production hardware tracks to complex, multi-year continuous glucose monitor (CGM) developments. Lisa and host Etienne Nichols explore the true financial scope of Design for Manufacturability (DFM), realistic blended hourly rates across global markets, and why shortcuts in early contextual validation often lead to catastrophic manufacturing overhead. Takeaways Phase-Gate Discipline Controls Financial Risk: Moving into high-cost tooling or manufacturing before proving core function in a low-fidelity mock-up risks turning a $1,500 prototype adjustment into a $150,000 production mold tool rework. Validate in the Real Operating Environment: Conducting customer interviews is insufficient if engineers do not observe the actual clinical setting; lighting conditions, sterile field constraints, and physical workflows dictate foundational hardware requirements. Benchmark Engineering Hours accurately: Standard hardware projects generally fall into three tiers: 2,000–3,000 hours for simple electronics integrations, 5,000–6,000 hours for multi-system electro-mechanical devices, and 10,000–30,000+ hours for high-complexity Class II/III systems (e.g., CGMs, surgical robotics). DFM Accounts for a Massive Secondary Investment: Completing the initial "golden sample" prototype is only half the engineering journey; preparing a device for mass production (assembly sequences, test fixtures, second-sourcing components) can demand an additional 2,500 to 7,000+ engineering hours. References OVA Solutions: Engineering group specializing in full-cycle medical device design, electronics, and firmware development. The Hardware Bible: Book authored by Lisa Voronkova detailing practical expectations and framework strategies for medical device development. Host LinkedIn: Connect with Etienne Nichols on LinkedIn for ongoing discussions with MedTech industry leaders. Feedback Call-to-Action We want to hear from you! What was your biggest takeaway regarding medical device engineering budgets and timelines? Have a guest recommendation or a topic you want us to dissect in an upcoming episode? Send your feedback, reviews, and topic suggestions directly to [email protected]. Etienne reads every message and responds personally to our listeners! Sponsors This episode is brought to you by Greenlight Guru. Learn more at www.greenlight.guru.
39 MIN
SEP 21, 2026
#474: Behind the QMSR Audits: The Top 5 FDA Citations & Risk Management Pitfalls
In this episode of the Global Medical Device Podcast, host Etienne Nichols sits down with Nikhil Mangale, Vice President of Quality at Kapstone Medical, to discuss the real-world impact of the FDA's Quality Management System Regulation (QMSR). Seven months post-implementation, the industry is seeing actual inspection data that shifts the focus away from superficial documentation updates and directly onto core quality system operations. Nikhil breaks down the top five areas where the FDA is issuing citations under the new regulation: risk management, supplier controls, complaint handling, Unique Device Identification (UDI), and corrective actions. The discussion highlights how the industry spent years worrying about renaming documents like Design History Files (DHFs) to Design and Development Files (DDFs), yet inspectors are bypassing mere translation projects to evaluate how information flows across living quality processes. The conversation offers actionable guidance on conducting thorough, multi-layered gap assessments for both active and legacy products. Nikhil provides strategic advice for small companies and startups on prioritizing risk management, handling supplier audit visibility, navigating ISO 13485 alignment, and weighing the benefits of participating in programs like MDSAP. Takeaways Prioritize Risk as a Living Process: Risk management must continuously integrate post-market feedback, complaint data, and nonconformances rather than remaining a static file archived after design release. Re-evaluate Supplier Audits for External Scrutiny: Routine supplier audit records are now accessible to FDA inspectors; ensure reports are well-documented, audit schedules are risk-proportionate, and findings are formally resolved. Implement a Three-Layer Mapping Strategy: Move beyond surface-level terminology updates (Layer 1) to establish subclause conformity (Layer 2) and verify operational evidence across interrelated processes (Layer 3). Maintain Open Design and Development Files (DDF): Unlike legacy DHFs that were closed at commercial launch, DDFs must remain active throughout the product lifecycle to evaluate ongoing design changes. Formulate a Defensible Quality Plan: When addressing gaps, document a risk-prioritized, sequential quality plan to show objective evidence of a structured compliance roadmap during an inspection. References FDA Compliance Program CP 7382.045: The FDA inspection guidance replacing QSIT, organizing surveillance around core QMS areas and specific regulations. ISO 13485:2016: The international standard for medical device quality management systems incorporated by reference into the FDA's QMSR. Etienne Nichols LinkedIn Profile - Connect with the host of the Global Medical Device Podcast. Feedback Call-to-Action We want to hear from you! What challenges are you experiencing with your QMSR implementation or risk management files? Send your feedback, reviews, or topic suggestions directly to [email protected]. We personally review and respond to every message from our listeners! Sponsors This episode is brought to you by Greenlight Guru.
33 MIN